Quick commissioning Finally, you need to set the setting P1910 to 1 to identify the motor data. However, I have set the alarm to jump out of the A0541 alarm before it can be eliminated. After the quick debugging, the P1910 is not set. Before the seniors said that they should press the start frequency conversion. To achieve motor data identification, how to press this specific?

A: Use P1910 for motor identification -
Note: The test must be performed in a cold state. Also make sure that the actual ambient temperature is correctly entered in the P0625 (factory setting is 20 °C) and the input ambient temperature must be performed after the motor is recognized after the quick commissioning (P3900) is completed.
P1910=1, give a run command: start motor parameter measurement.
A0541 will continue to flash; multiple measurements will be completed by injecting a short pulse current into the motor with a “click” sound. When the internal motor parameters are calculated later, “busy” will appear on the BOP panel.
Then you have to wait until the device automatically "stops" the self-test (until P1910 = 0, the self-test process ends).

"Before, there are predecessors here who want to press the start of the inverter to achieve motor data identification. How to press this specific?"
You can start the inverter to start motor data identification by pressing the start button on the inverter's panel.

Bushing Cover For Switches

The product is made of synthetic silicone rubber vulcanized at high temperature, never changing, high flexibility, tear, product life can reach 50 years, has good insulation performance, insulation strength ≧20KV/mm, insulation resistance ≧10, reasonable design, easy installation.

The buckle structure is easy to disassemble and reuse during maintenance. High and low temperature resistance, can be used in the range of -60℃-190℃. Uv resistance, excellent hydrophobicity, aging resistance, meet the long-term outdoor operation.

Applications:

Provide insulation and protection for various incoming and outgoing connection points of insulation switches, vacuum switches and fuses.

Features:

1.Suitable for 1-35KV.
2.Radiation cross linking materials (Polyolefin or EPDM rubber ).
3.Quick and easy installation.
4.Avoid short circuit and leakage.
5.Facilitate routine inspection and maintenance.
6.Resistant to moisture and dust.
7.Meet RoHS Stand.
8.Customized

We are the professional manufacturer of Electrical Tapes,Insulating Tape and Bushing Cover in China for more than 25 years,if you want to know more information about our company and products, please visit our website.


Bushing Cover For Switchges,Transformer Protection Sheath,Transformer Protection Sheath Dress,Heat Shrinkable Insulation Cover For Transformer

CAS Applied Chemistry Materials Co.,Ltd. , https://www.casac1997.com