Greno 11kv 12kv Sf6 Gas Load Break Switch

Model NO.: GSC-SC6
Altitude: 2500m
Standard: IEC,ANSI,Ceb,GB
Trademark: GRENO
Transport Package: Carton, Wooden Case
Specification: Phase distance: 210mm
Origin: Xiamen
SF6 load break switches are designed for switching circuits with currents up to 630 A in 6 kV, 10 kV, and 20 kV/24kV / 50 Hz three-phase A.C. networks.

Professional service ,win-win business
Features of the products:
1) Designed for our GSM serie AIS ring main unit(RMU) switchgear and could also fit to all kinds of similar switchgears.
Greno 11kv 12kv Sf6 Gas Load Break Switch



2)Insulation ability for arc-extinguishing is increased(when switchgear is at open status) because SF6 gas was filled with 0.03Mpa~0.04Mpa pressure
Safely make the whole size smaller.
 
3)Best material:The copper contacter contains more than 99.95% Cu content and special production process guaranteed the abrasion rigidity .We called this material named T2 copper.


4)Increased phased distance :210mm ,particular design lengthened  air and creepage distance.
Greno 11kv 12kv Sf6 Gas Load Break Switch


  

 
5)Strictly control quality we chose the best quality epoxy resin although it was expensive.

Making a belt transect with epoxy resin to test before every production is a must.
According to test datas ,the major material quality (such as bending strength, tensile strength,impact strength etc) is well controlled.

6) Internal contact terminals are of permanent magnetism material.
The arc becomes thinner and thinner thus naturally exthinguish in SF6 gas when LBS switches to open position.
"Warmly wecome to Send us any enquiries anytime"
Greno 11kv 12kv Sf6 Gas Load Break Switch



We focus on every detail 
Item NO. Name Unit Technical parameters
Load break switch panel
1 Rated Voltage Un kV 12 24 36
2 Rated Frequency Hz 50 50 50
3 Rated Current A 630 630 630
4 Rated Load Breaking Current A 630 630 630
5 Rated Short Time Withstand Current(rms) kA 20 20 20
6 Rated Short Time Duration s 3 3 3
7 Rated Peak Withstand Current  kA 50 50 50
8 Rated Closed Switch - Off Current A 630 630 630
9 Rated Cable Charging Breaking Current A 10 10 10
10 Rated Active Load Breaking Current A 630 630 630
13 Earthing Switch 2s Short Time Withstand Current  kA 20 20 20
14 Rated Short-Circuit Current Making Times  times 2 2 2
15 Rated Current Breaking Times times 10 10 10
16 Mechanical Endurance  Load Break Switch times 3000 3000 3000
Earthing Switch times 2000 2000 2000
17 SF6 gas anual leakage rate≤   /year 0.10% 0.10% 0.10%
18 Rated Insulation Level Unit Technical parameters
1min Power Frequency withstand voltage(rms) On isolating distance kV 48 60 110
Phase to Phase  kV 42 50 85
Phase to Earth kV 42 50 85
Lightning impulse withstand voltage(peak) On isolating distance kV 85 145 215
Phase to Phase  kV 75 125 185
Phase to Earth kV 75 125 185


Our Services
12 months warranty or longer( Negociable)
Type test, technical and marketing support.   
Warmly welcome customized design.
After-sales service ..
Greno 11kv 12kv Sf6 Gas Load Break Switch


 FAQ:
1.What is the payment term?
 T/T, wire transfer, west union
2. What kind of VCB do you have?
We have 12kv,24kv,36kv,40.5kv lateral type and withdrawable type vacuum circuit breaker.
3. Warranty period?
Normally 12 months.
 3.How about type test?
Our client passed type test in Europe, and we also type tested in China.
 

MPPT Controller

MPPT Controller,Mppt Solar Inverter,MPPT Solar Controller,MPPT Solar Charge Controller

Jinan Xinyuhua Energy Technology Co.,Ltd , https://www.xyhenergy.com