Model NO.: GSC-SC6
Altitude: 2500m
Standard: IEC,ANSI,Ceb,GB
Trademark: GRENO
Transport Package: Carton, Wooden Case
Specification: Phase distance: 210mm
Origin: Xiamen
SF6 load break switches are designed for switching circuits with currents up to 630 A in 6 kV, 10 kV, and 20 kV/24kV / 50 Hz three-phase A.C. networks.Professional service ,win-win business
Features of the products:
1) Designed for our GSM serie AIS ring main unit(RMU) switchgear and could also fit to all kinds of similar switchgears.
2)Insulation ability for arc-extinguishing is increased(when switchgear is at open status) because SF6 gas was filled with 0.03Mpa~0.04Mpa pressure
Safely make the whole size smaller.
Â
3)Best material:The copper contacter contains more than 99.95% Cu content and special production process guaranteed the abrasion rigidity .We called this material named T2 copper.
4)Increased phased distance :210mm ,particular design lengthened  air and creepage distance.
 Â
Â
5)Strictly control quality we chose the best quality epoxy resin although it was expensive.
Making a belt transect with epoxy resin to test before every production is a must.
According to test datas ,the major material quality (such as bending strength, tensile strength,impact strength etc) is well controlled.
6) Internal contact terminals are of permanent magnetism material.
The arc becomes thinner and thinner thus naturally exthinguish in SF6 gas when LBS switches to open position.
"Warmly wecome to Send us any enquiries anytime"
We focus on every detailÂ
Item NO. | Name | Unit | Technical parameters | |||
Load break switch panel | ||||||
1 | Rated Voltage Un | kV | 12 | 24 | 36 | |
2 | Rated Frequency | Hz | 50 | 50 | 50 | |
3 | Rated Current | A | 630 | 630 | 630 | |
4 | Rated Load Breaking Current | A | 630 | 630 | 630 | |
5 | Rated Short Time Withstand Current(rms) | kA | 20 | 20 | 20 | |
6 | Rated Short Time Duration | s | 3 | 3 | 3 | |
7 | Rated Peak Withstand Current | kA | 50 | 50 | 50 | |
8 | Rated Closed Switch - Off Current | A | 630 | 630 | 630 | |
9 | Rated Cable Charging Breaking Current | A | 10 | 10 | 10 | |
10 | Rated Active Load Breaking Current | A | 630 | 630 | 630 | |
13 | Earthing Switch 2s Short Time Withstand Current | kA | 20 | 20 | 20 | |
14 | Rated Short-Circuit Current Making Times | times | 2 | 2 | 2 | |
15 | Rated Current Breaking Times | times | 10 | 10 | 10 | |
16 | Mechanical Endurance | Load Break Switch | times | 3000 | 3000 | 3000 |
Earthing Switch | times | 2000 | 2000 | 2000 | ||
17 | SF6 gas anual leakage rate≤ |  | /year | 0.10% | 0.10% | 0.10% |
18 | Rated Insulation Level | Unit | Technical parameters | |||
1min Power Frequency withstand voltage(rms) | On isolating distance | kV | 48 | 60 | 110 | |
Phase to Phase | kV | 42 | 50 | 85 | ||
Phase to Earth | kV | 42 | 50 | 85 | ||
Lightning impulse withstand voltage(peak) | On isolating distance | kV | 85 | 145 | 215 | |
Phase to Phase | kV | 75 | 125 | 185 | ||
Phase to Earth | kV | 75 | 125 | 185 |
Our Services
12 months warranty or longer( Negociable)
Type test, technical and marketing support.  Â
Warmly welcome customized design.
After-sales service ..
 FAQ:
1.What is the payment term?
 T/T, wire transfer, west union
2. What kind of VCB do you have?
We have 12kv,24kv,36kv,40.5kv lateral type and withdrawable type vacuum circuit breaker.
3. Warranty period?
Normally 12Â months.
 3.How about type test?
Our client passed type test in Europe, and we also type tested in China.
Â
MPPT Controller,Mppt Solar Inverter,MPPT Solar Controller,MPPT Solar Charge Controller
Jinan Xinyuhua Energy Technology Co.,Ltd , https://www.xyhenergy.com