Description
ZW8-12 series outdoor high-voltage vacuum circuit breaker is a kind of three-phase outdoor high-voltage switchgear of rated voltage 12kV and AC 50Hz.
Its population structure is three-phase together box type. Three-phase vacuum arc-extinguish chamber palaces in a metal cabinet, using the SMC insulating material to insulate inter-phase and phase to earth, which is reliable in performance and high in insulating intensity.
ZW8-12G is combined with ZW8-12 circuit breaker and isolating sword, called combination circuit breaker and used as a section switch.
Applying ambient conditions
1.Ambient temperature:-10ºC~+40ºC.
2.The height above sea level:≤1000m(besides the special requirements).
3.Relative humidity:the average humidity of a day should be no more than 95%;the average humidity of a month should be no more than 90%.
4.Saturated vapour pressure:the average pressure of a day should be no more than 2.2kPa;the average pressure of a month should be no more than 1.8kPa.
5.Earthquake intensity:not exceed 8 degrees.
6.It should be installed in the places without fire,explosion,serious filth,chemical erosion and violent vibration.
Item | Unit | Parameter | |||||
Rated Voltage | kV | 12 | |||||
Rated Current | A | 630 | |||||
Rated Short-circuit Breaking Current | kA | 6.3 | 12.5 | 20 | |||
Rated Short-circuit Making Current (Peak) | kA | 16 | 31.5 | 50 | |||
Rated Peak Withstand Current | kA | 16 | 31.5 | 50 | |||
Rated Short-time Withstand Current | kA | 6.3 | 12.5 | 20 | |||
Rated Insulation Level | 1min Power Frequency Withstand Voltage (Dry Test) |
kV | 42 | ||||
Lightning Impulse Withstand Voltage (Peak) | kV | 75 | |||||
Rated Operating Sequence | Â | O-0.3s-C O-180s-CO | |||||
Mechanical Life | times | 10000 | |||||
Rated Short-circuit Current Breaking Times | times | 30 | |||||
Rated Closing Voltage of Operator | V | 110, 220 | |||||
Rated Opening Voltage of Operator | V | 110, 220 | |||||
Clearance Between Open Contacts | mm | 11± 1 | |||||
Over travel of Contacts | mm | 3 | |||||
Three-phase Opening/Closing Synchronization | ms | ≤ 2 | |||||
Closing Bouncing Time | ms | ≤ 2 | |||||
Average Opening Speed | m/s | 1.0± 0.2 | |||||
Average Closing Speed | m/s | 0.7± 0.15 | |||||
Opening Time | Highest Operating Voltage | s | 0.015~0.05 | ||||
Lowest Operating Voltage | s | 0.03~0.06 | |||||
Closing Time | s | 0.025~0.05 | |||||
Main Loop Resistance of Each Phase | μ Ω | ≤ 120 | |||||
Total Thickness of Permissible Wear of Moving and Static Contacts | mm | 3 |
PLS FOLLOW MY LINKEDIN
Joimmy Chow  /  Guanchu Tao |
General-purpose rectifiers belong to the most widely used category of rectifiers, and their classification is relative to those with special functions, such as fast, high-frequency, and so on.
Our universal rectifiers are of original quality, complete models, high visibility, affordable prices, and fast shipping!
Rectifiers,General Purpose Rectifiers,Rectifier Diode,General Purpose Rectifier Diodes
Changzhou Changyuan Electronic Co., Ltd. , https://www.cydiode.com